Daily dispatch system

Daily dispatch system

Article 1 Dispatchers at all levels should frequently go deep into the production line and construction site to understand and master the production schedule and project quality, the safety situation of the main working place in the mine, often understand the mineral processing production, the completion of various indicators, and understand the use of vehicle scheduling. Situation, understanding of labor discipline, etc.
Article 2 The dispatcher must understand and master the production and operation dynamics of the whole company, and always remind the company leaders to seize the important links and major contradictions in the production and operation activities, and urge the relevant departments to solve practical problems. It mainly includes the following aspects:
1. The supply of major materials;
2. The completion of major production technical indicators;
3, metal balance;
4. Safe and civilized production;
5. Strengthen the balance of mining and mineral processing;
1) In-depth production of the first line according to the monthly production plan, check the production site;
2) Organize the mining and acceptance work;
3) Adjust the grade of ore selected in time to ensure balanced production;
4) Grasp the work of the disabled.
6. The completion of the tasks assigned by the leadership.
Article 3 To strengthen production scheduling, problems arising in production shall be resolved in a timely manner, and key technical projects and maintenance projects shall be seized to ensure completion on time.
Article 4 The monthly production operation plan shall be released on time, and the units will be reached under the production operation plan for the next month before the 26th of each month.
Article 5 Responsible for convening and presiding over two regular monthly meetings.
Article 6 When dispatching personnel to report personal or other disaster accidents, they shall promptly find out the situation, immediately report to the company's leaders and organize personnel for rescue.
Article 7 In the event of an accident in key equipment, the investigating personnel shall immediately report to the company's leaders and organize relevant units to take emergency measures, organize personnel and materials to assault and repair, and resume production as soon as possible.
Article 8 The dispatcher must do the information spirit and transfer quickly. For the problems in the production activities, the work of the grassroots reporting, the dispatching instructions, the leadership instructions, and the things that are issued, the records must be carefully filled in.

Holter ECG Monitoring System

Introduction

Holter ECG Monitoring Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.


Analysis Software Function

1.The rate of checking RR wave up to 99.9%, which increased the accuracy of analysis without losing wave.

2.AI histogram function which can directly distinguish various abnormal ECG which can analyze faster.

3. Dynamic ECG [Channel Correct" function, which can correct mistakenly wearing that makes the analysis more accurate.

4.Lorenz and Demix analysis function, which can analyze more faster, more accurately. Single medical case can be completely analyzed in 10 min, which can reduce the physician`s work.

5.ST can be displayed in many kinds of form, which ensures that analyzing ST- Trends Diagram comprehensively, observing the whole or partial ST variety to analyze the specific area of myocardial ischemia.

6.Atrial fibrillation function can be recognized automatically and can distinguish atrial fibrillation case, give advice and generate analysis report .

7.Unique Cardiac Fatigue Index function, which can judge index of Cardiac Fatigue .High-risk groups can be found and early intervention treatment can be taken by the index, which can effectively judge the heart age and predict SCD (Sudden Cardiac Death).

8. P-wave analysis function, which can check cardiac arrhythmia (such as AVB).

9.According to the requirement of patients, options can be selected freely while printing report, which can save physician `s time

10. ECG can be printed by various forms according to the user`s requirement.

11.Pacemaker analysis function, which can analyze different pacemakers(such as AAI,VVI,DDD).

12.The comprehensive analysis system of stand-alone version with network version ,users can freely select any model.

13.Wire and wireless simultaneously transfer mode ,which reduce complicated performance.

14. Dynamic ECG and static ECG analysis system ,which reduced complex operations.

15. Time Domain and Frequency Domain function on HRV module can reflect the moderation effect of sympathetic and parasympathetic to the heart rate.

16.HRT function can predict myocardial infarction which has clinical value.

17.ST function which can check the exact time and length of myocardial ischemia in 24 hours.



Holter Monitor,Holter 24 Hours,Holter Recorder,Holter Ecg Monitoring System

Changchun Yingwang Times Digital Co., Ltd. , https://www.ccsdsm.com